Range hood on lighting circuit. If the control module breaks, it can make the .

Range hood on lighting circuit If the fan unit has a cord, it must be plugged into a receptacle on a dedicated circuit. Broken switches. 16(B)(4)(3). The on/off switch controls power flow to the fan and light on a range hood. Gas stove isn’t required to be a SABC If I may ask do you know why does nec requires a light and and exhaust fan to be hard wired on its own circuit, guess I just don’t understand how a light bulb and a fan that draws very little amps Adding range hood to 15A light circuit. Undercab lights on kitchen Troubleshooting Problem Possible Cause If the range hood or LED light does Check if the range hood has been plugged in, make sure that not operate after installation: all power has been turned back ON, fused not blown and all electrical wiring are properly connected. Just be careful to not overload the circuit breaker. But you should not forget some major points while using this lighting circuit. Study with Quizlet and memorize flashcards containing terms like is not, clock outlet, two 20-ampere circuit &GFCI and more. Vent fan/range hood: Hard-wired vent fans or range hoods are typically connected to one of the kitchen's lighting circuits. Follow these steps to ensure a smooth installation: 6 steps to hardwire a range hood Range-hood-hardwiring-process – kitchenandrangehood. Share Sort by: Best. If the cord is not long enough, you can use an extension to reach the outlet. It will also help you pass the inspection based on the local code since it is safer. Return any part for 365 days. 4. The wiring harness plugs into the main harness and the sockets clip into the light housing. If you wish to do this, the above conditions must be met, plus these two more: The range hood cannot be rated higher than 50% of the branch circuit rating. Range hoods are tricky things, aren’t they? Symptom: Neither Lights Nor Fan Work Causes: Bad user interface. But you can’t even use your kitchen smallholder. Once you’ve identified the issue and gathered your tools, follow these steps: 1. This procedure shows how to replace the electronic control board in common Kenmore, Broan, Whirlpool, Frigidaire, Electrolux and GE range hoods. 2024. Disconnect all wiring to the thermal fuse. Then, get the parts you need fast. Improve this question. It can simply be a blown-out bulb causing a lack of lighting, or it can be a serious fault relating to the control panel inside. D. Read More. The motor will be on a separate switch on another circuit entirely. It can never be connected to a kitchen outlet in a small-appliance branch circuit(SABC). (FIG. DavidTu Member. Since the switch is an essential component, any malfunction can affect the performance of your range hood light. There is an accessible 12/3 wire that I would like to use for the power source. To fix this issue, you will need to disassemble your rangehood and inspect wires with the power switched off. If the filament is broken, it’s time for a new bulb. 8K views 1 reply 2 participants last post by rjniles Sep 16, 2016. 11C3]. While this may work, I'd suggest putting it on it's own circuit, preferably a 20 amp circuit. Used a lead solder in a kitkchen range hood repair: Technical Repair: 14: Dec 4, 2021: L: Newbie needs help: converting range hood lighting from halogen to LED: General Electronics Chat: 39: Mar 21, 2018: 1: Range Hood Fan/Light Circuit Went Pop Then Dead: General Electronics Chat: 10: Aug 9, 2017: M: Confusion with Range Hood Blower Fan Motor 422. This process ensures a seamless and integrated setup for your kitchen’s ventilation Study with Quizlet and memorize flashcards containing terms like AFCI protection is not required for appliances that are supplied by branch circuits rated at ____ volts such as for electric ranges, cooktops, and built-in ovens. As per NEC 210. (In some homes, the range hood is tied to a small GE range vent hood lights not working? Use our DIY troubleshooting & videos. Join Date These hoods typically consist of a fan and a light, which need to be properly wired in order to function effectively and safely. I believe the intention of the code is to insure the microwave vent will be on a dedicated circuit as they come with a factory attachment plug 210. Troubleshooting Your Range Hood Inspect the circuit board. Lid & Cover Parts Broan Capacitor Parts Broan Circuit Board & Timer Parts Broan Drawer Parts Broan Duct & Venting Parts Broan Fastener So my question is can I run my range hood on the same circuit as my undercabinet lighting, or does the range hood truly need its own dedicated 20A circuit? The UC lighting will be in its own 15A circuit Again new to Reddit sorry if this is the wrong sub or something Share Sort by: Best. Broken light socket and fan motor . 2x 20amp circuits for countertop receptacles (one circuit will have 2 receptacles, the other will only have one). Track Order. This is the next step in the process. 16(B)(4)Range Hoods. EXTERNAL DIAGRAM OF RANGE HOOD. Remove the cover: Carefully remove the cover of the range hood light fixture. Additionally, the wiring allows for the proper functioning of the hood’s lights, providing adequate illumination for your cooking activities. Replace the range hood light bulb socket. I realize this addition violates this section Older residential codes required range hoods to be connected to a dedicated circuit but electronic appliances are more energy-efficient these days. You’ve got the know-how to choose the perfect light bulb for your range hood. Range hood circuit board replacement varies by model. Q&A. I want the light on it to turn on when I flip the switch to turn on my uncercab lights. - On the same circuit is another recessed light over sink and an Turn off the power to the range hood before inspecting any wiring. If your rangehood’s fans work, but the lights are still switched off, you are experiencing issues with faulty wiring, blown bulbs, or a problem control board. What color. 16(B)(4). Turn off power and disconnect electrical supply - Locate the circuit breaker for the vent hood and turn it off. a. Switch Troubleshooting: The Next Step Wiring: The diagram illustrates the wiring connections between the power supply, switches, and other components of the range hood, such as the fan motor or lights. This easy-to-follow repair guides explains how to replace Here are the most common reasons your Broan range vent hood lights aren't working - and the parts & instructions to fix the problem yourself. Old. I know I'll need to change the switch from [SPST] to [SPDT], but I'm less clear on how to add load to the Low (dim) side to get the bulb to (roughly) 50% illumination -- the existing lighting load is a dimmable LED Edison bulb. I want to know if this is Rangehood Fan Works but Lights Not Workin g. To be safe, run your range hood on a dedicated 20 amp circuit breaker. Click to expand Why do you say that? Don't all 15 & 20A circuits have to be AFCI under NEC 2008? With the old range hood removed, you’re now ready to prepare the range hood for wiring. Member. If this switch fails, it will prevent electricity from reaching the fan or light even when toggled on. I) Use UL approved clamps to secure all cables to hood and box. Better Life. 8. Range hoods shall be permitted to be cord-and-plug-connected with a flexible cord identified as suitable for use on range hoods in the installation instruc-tions of the appliance manufacturer, where all of the fol-lowing conditions are met: (1) The flexible cord is terminated with a grounding-type attachment plug. with the exception of a dedicated 20A circuit for the range hood. triggercash • You need 2 countertop circuits, range and hood can share. Problem 29 Range hood fan–light. A circuit board will be a I would use a 15 amp circuit for the lights and heaters, not a 20. The decision to install a range hood in your kitchen is an important one. The range hood supports a hardwired connection The range hood can not be rated higher than 50% of the branch circuit rating* Move range hood to lighting circuit. You can use a lighting circuit for connecting your range hood. But, a dedicated No, Rangehood doesn’t need any dedicated circuit for the connection. I'm thinking of 422. Range hoods shall be permitted to be cord-and-plug connected with a flexible cord identified as suitable for use on range hoods in the installation instructions of the appliance manufacturer, where all of the following conditions are met: (1) The flexible cord is terminated with a grounding- type attachment plug. Disconnect the wires leading to the light switch. Does a range hood need a dedicated circuit? No. But, a dedicated circuit takes up extra space in the electrical panel. The cord for the range hood must have a grounded-plug. Fix things more easily! En español. When installing a range hood, you have two options to run power to the hood. 1) Yes, a range hood requires a dedicated circuit and is not allowed to be shared with the kitchen countertop or kitchen lighting circuits. The current. As you know range hoods are required to have their own circuit based on 422. You can use a lighting circuit or hardwire to connect your range hood. Conclusion. Upvote #12 01-06-15, 01:44 PM S. Look for signs of wear such as fraying or exposed wire. The range hood is rated at less than 50% of the branch circuit rating. If a 20-amp circuit serves only one (1) bathroom, lights and fans can be on the From my research it seems that the majority of range hoods are connected by hard wiring. Time required 45 minutes or less. Faulty Light Bulb. A malfunctioning circuit board can also cause the light to blink. Given all this, I would look at pairing the dishwasher and disposal, if feasible, and also at putting the range hood and the undercabinet lights on the same circuit, given that Restore the power to the range hood and ensure that the lights and fan are operating correctly. 23(A) (2), hardwiring the range hood to a lighting circuit is allowed when the below conditions are met: 1. Service Parts. The most straightforward solution is to check the bulb. The kitchen has a 15A dedicated circuit for lights. Use a voltage tester to confirm that the power is off before Light circuit connections; Control board connections; To use a wiring diagram: Identify the model number (e. 23(A) and NEC 210. The most common reason for a blinking range hood light is a faulty or loose light bulb. , SU900, SUT900) How can I troubleshoot flashing lights on my Sirius range hood? Flashing lights often indicate a specific problem. I assume if I, say, added an outlet serving my backyard on that circuit (which is right next to the kitchen, and this might be a reasonable thing to do since this I'm remodeling my kitchen and am wondering if my range hood needs to be on a dedicated circuit or if I can run a line. Make wiring connections following appropriate diagram. dman535 Discussion starter. We need to add a range hood to the kitchen. If they still don’t work, unplug your range hood and check the wiring It is easy to adjust the wiring to power the hood lights from the same circuit as the kitchen lights, the fanciest hood I have done the owner wanted a “mood light” around the rim, I used sealed rope light and 2 reflector lamps for cooking both were controlled with the fan on a wall switch (the couple did not want to hassle with a step stool Troubleshooting If the range hood or halogen light does not operate • Check if the range hood has been plugged in, make after installation: sure that all power has been turned back ON, fused not blown and all electrical wiring are properly con- nected. Step 4: Prepare the range hood for wiring. Complete the wiring diagram using colored pens or pencils to show the conductors' insulation color. Sometimes, rodents can chew on wires, or wires may become disconnected from their terminals, especially around high-traffic areas like the control panel or motor. Why is the light not working on my Broan range hood? When the light won’t turn on in your Broan range hood, try replacing the light bulb. Cavie Senior Member. I have a simple 120v range hood with two controls: Fan [High/Off/Low]; Light [On/Off]; I'd like to convert the light switch to [High/Off/Low]. g. To determine whether the light switch is faulty, test it with a • A range hood / microwave combination can be cord-and-plug connected if the circuit is an individual (dedicated) branch circuit. It might be able to share the circuit with the disposal. Looking at the Range hood control not working: Used a lead solder in a kitkchen range hood repair: Newbie needs help: converting range hood lighting from halogen to LED: Range Hood, Helogen Lights not lighting: Confusion with Range Hood Blower Fan Motor - 9 Wires Range hood; Dishwasher; Garbage disposer; Under-cabinet lights; electrical; kitchens; code-compliance; Share. Before you do anything else, try replacing the bulbs. If the control module breaks, it can make the Hey guys, I am trying to figure out if I can wire my range hood into my undercabinet light system. A dedicated circuit can save you from the risk of overloading. , The range hood exhaust fan/light is supplied by an _____ branch circuit (supplies no other load) from Panelboard B (B-25). i want to use 12/2 wire, while i'm at it, for any future expansion to microwave/hood. Rashmi Sinha What I've got at the moment: dedicated circuits for fridge, microwave, dishwasher, oven and cooktop. where the range hood will be installed? b. Open comment sort options Controversial. Electrical - AC & DC - Electrical Rough In for Range and Range Hood - What is the proper height to put in the outlet for an electric range? I set the top of the 4 x4 metal box at 8 above slab since my last range the plug is way down there. A range hood can run on a circuit with more than one appliance. Grounding: The diagram indicates the grounding connections required for safety Putting a range hood on a lighting circuit is easier and can be set up quickly. 2 reads "supplemental equipment and lighting" but specifies a gas range or oven. Examine the light socket for damage. Use proper wire nut sizes for number and size of wires. 29 posts · Joined 2015 Add to quote; Only show this user #1 · Sep 15, 2016. While wiring a range hood may seem like a daunting task, it is actually a relatively straightforward process that can be accomplished by following a How to Replace Range Vent Hood Light Switch. Jump to Latest 1. This usually 422. If that circuit is now an SABC, is it allowed for the range hood to be hardwired to it? I see 210. If lights flicker or don’t turn on, check bulb connections. Flip it off and on to reset it. Wiring Hunter Skysail ceiling fan. Hardwiring a range hood involves directly connecting the hood’s wiring to your home’s electrical system, bypassing the need for a traditional plug-in power source. Page 16: Maintenance Ex 2: A receptacle can be connected to the small-appliance branch circuit to supply a gas-fired range, oven, or counter-mounted cooking unit. Understanding what type of wiring your range hood needs and whether it requires its own dedicated circuit is essential in creating a safe and efficient appliance. Quick view. If you have ruled out bulb issues and suspect that the problem lies with the wiring or switches, follow these troubleshooting steps: What Is The Clean Air Function On A Zephyr Range Hood? The clean air function on a Zephyr range hood helps to improve the air quality in your Edit: Most common way it is done is a 15amp circuit for the stove and range hood. in the ceiling box Step-by-Step Guide: How to Fix Range Hood Light. I've removed the light so now can I use the light's wiring for the range hood? - There is 1 black and 1 white wire. Add a Comment. A lot of lighting circuits use a 15 amp breaker, a 7 amp blower would be almost 1/2 of that. 1. The circuit board controls the electrical connections and may How to Replace Range Vent Hood Light Switch. While inspecting the wires, check wires connecting to lights, circuit boards, and control panels. No Gfi. How many luminaires are connected to the kitchen lighting circuit?4. Range Hood On Small Appliance Circuit. Turn off the power: Before working on any electrical component, always turn off the power to the range hood at the circuit breaker. This step-by-step repair guide shows range hood circuit board replacement. OPTION 1 Hey there, I have some basic electrical knowledge and since the second out of two halogen bulbs on my range hood blew out, I thought it would be the time to replace those by 3W LED COBs (which are labelled as 12V AC or DC). Rating refers to the number of amps. Wiring failures. Requirement: A range hood requires a dedicated circuit, and hardwiring or a receptacle within reach of the hood However, if the rangehood socket seems to be getting enough power, there may be loose or faulty wires inside the range hood. 1-800-269-2609. Figure 12 shows the primary side of the driver (120V) connected to the circuit board. The first, easiest option, so long as your range hood has a three-pronged plug, is to plug it into a standard 120V outlet. 16(B)(4) Range Hoods. 2) Two separate bathrooms are allowed on the same dedicated 20 amp circuit, but only for the bathroom receptacles. Could "supplemental equipment " be a range hood? If so why only on a gas range. The black wire connects to a small rectangular piece of metal that was attached to top of can. Using a Lighting Circuit. This means that as long as your range hood isn’t sharing the circuit with a Putting a range hood on a lighting circuit is easier and can be set up quickly. I removed the filters and the light bulbs. Example: To avoid plunging the whole kitchen into darkness if an appliance trips a breaker, kitchen lights need their own circuit separate from the outlets. Many cord and plug connected range hoods are also listed as microwaves and Which circuit would be the best to tie in an exhaust fan for the range? What about under-cabinet lighting? Locked post. Dedicated circuits take up space in the panel: A dedicated circuit can save you from the risk of overloading. To determine if the selector switch is defective, consult your vent hood’s wiring diagram and use a multimeter to test the switch for continuity. Safety must be the priority when installing a range hood. Now have 3 small appliance circuits, the 3rd one to the single countertop receptacle for the plug in countertop microwave. 23(A)(2) says fastened in place equipment (assuming built in microwave) cannot exceed 50% of the circuit rating if there are lights or receptacles feeding non-fastened-in-place equipment. That way, your lights stay on even if a countertop appliance overloads. If you're going to put in a cord connected range hood or microwave/hood combination, that receptacle needs to be an in or hard-wired. INSTALLING THE CHARCOAL FILTER WIRING DIAGRAM. New comments cannot be posted. Location SW Florida. If your hood does not have a three-pronged As a result, the range hood light will flicker. Repair difficulty. The control module is the circuit board inside that runs the range hood fan and blower. Figure 12: Connect the Power Wire to the LED Driver Figure 13: Wire to the Circuit Board Note: The connector can be found inside the hood. If you want to check, circuit boards are usually located underneath the range hood or behind it. Range hoods and over-the-range microwave ovens with integral range hoods shall be permitted to be cord-and-plug-connected with a flexible cord identified as suitable for use on range hoods in the installation Lighting issues are common electrical problems in range hoods. Always use a bulb with the correct wattage and type as specified in your range hood‘s manual. Range hoods shall be permitted to be cord-and-plug connected with a flexible cord identified as suitable for the use on range hoods in the installation instructions of the appliance manufacturer, where all of the following conditions are met: Bob, your reasoning is right on the money! See page 206 of the 2005 Analysis book. The range hood supports a hardwired connection. Check the Light Socket. Wiring Diagram Six Speed with Type GU10 Bulb Six Speed with Type MR16 Bulb Page 16 Range hood or microwave, if it's receptacle connected, it has to be dedicated circuit. 1. If it's simply a range hood, it can be hard wired and on a lighting circuit. Read the specs of the hood you can probably connect the range hood to the lighting I was told recently that a separate dedicated circuit is required for the range hood fan/light in a small single family residential kitchen. . HomeRange Hood Transformer (TF-N) Click to enlarge. Add to cart Add to cart. Just remember to stay within the safe wattage limit and aim for a brightness Plug in the range hood light’s wires (x 2) into the jack. Replace the Circuit Board. Just changed your range hood light bulb but it still won't come on? The light socket might be to blame. 2) Two separate bathrooms are allowed on the same Hard-wiring the range hood to a lighting circuit is allowed when all of the below conditions are met. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright 422. Also check this: Can You Use a Dryer Vent For the Range Hood. Test and inspect the wiring: Once the range hood wiring is complete, it is crucial to test and inspect it for any issues or errors. So does that mean the wall outlet needs to be removed and get the original wiring back out? Historically, range hoods were put onto a general lighting circuit. It can also be hardwired or hooked into a receptacle on a lighting circuit. Check back soon! View. The other two jacks have jumpers in them. I only needed a medium sized crosspoint screwdriver to remove 5 screws that hold up the light housing. Thread starter Ravenvalor; Start date Dec 2, 2021; Status Not open for further replies. Range Hood Transformer (TF-N) $29. Range Hood Light Kit (LK-100) Electrical - AC & DC - range hood wiring question - hey all, i am running wire for a new range hood (small unit fan with light hardwired). If the breaker trips immediately, there may be a short circuit or Replace the electronic control board with the manufacturer-approved replacement part if the control board no longer activates the fan motor or lights. Being in the kitchen over the counter area tends to make the cmp more cautious. Apr 16, 2011 #4 NO AFC. The following is a layout for the lighting circuit for the Kitchen. I turned off the power to the range hood at the breaker box first. Ensure bulbs are securely fastened and not burnt out. Pulling it off the microwave circuit would be a no as you'd be overloading the circuit if the microwave and vent was running at the same time. Range Hood LED Switch (BP8) The ZLINE CB9 Range Hood Circuit Board is designed to fit all ZLINE Island and Wall Mount Range Hoods. With the old range hood removed, it’s time to prepare the new range hood for wiring. Please verify that the transformer you are replacing has the model number "BL-10" on the information sticker, as shown in this listing photo. And this includes being aware of the wiring requirements. Check if the bulb is firmly screwed in and replace it if necessary. The original bulbs are 12V 20W G4 halogen bulbs. Save Share What size conductors are3. 2. If you are missing parts or if you require replacement parts, please contact our customer service team at vissani@conglom. Open comment sort options Note that the range hood is a fastened in place appliance whether cord and plug or hardwired so it falls on the 50% rule when considering general purpose branch circuits regardless. Here are eight ways to troubleshoot your range hood fan and lights. Apr 17, 2011 #5 Cavie said: NO AFC. By chatting and providing personal info, you understand and I need to replace the kitchen range hood lights and having difficulty finding the right ones to replace. My question is: what circuit do I put the range hood on? The ZLINE LK-CAT1-CREE Range Hood Light Kit is designed to fit ZLINE Wall, Island and Insert Mount Range Hoods. electrical; wiring; exhaust-fan; Bathroom Exhaust Fan with Light - Wiring. If the light doesn’t work after replacing the bulb, the socket, switch or electronic control board could be causing the failure. That practice is still acceptable. 52(B)(2) says "No other outlets ", but the range hood is hardwired, not on an outlet. If the hood has a BLACK JUMPER WIRE, it must be cut and the end stripped as shown. Remove the old bulb and visually inspect it for signs of damage or breakage. If I ever decide to change to micro hood some day down the road, pull 3rd small appliance back up the wall cavity, remove hood from lighting circuit, and drop the spare circuit back down Read the specs of the hood you can probably connect the range hood to the lighting circuit. Replace range hood wiring cover. Lighting issues in range hoods are often a result of Reasons for Blinking Range Hood Light 1. , As you study the cable layouts in I am installing a new range hood, and know little about wiring. So, on a 15 A circuit, the range hood must be See more Your options here are to put it on its own circuit (always works, but takes up panel space) or to put it on a lighting circuit (always works for hardwired hoods, may work for cord-and-plug Most don't, but depending on the unit some range hoods do require a dedicated circuit. Over-the-range microwaves with vent fans usually need a dedicated circuit. This is just a garden variety hood, probably Many homes are constructed with a simple hardwired hood on a 15A lighting circuit, then the MW is added later on the same ckt. supersnake83. dtabb14. The red wire is always hot, and is connected to a 12/2 that runs to The Bulb Check: A Quick Fix. Circuit Board Problems. Based on my kitchen layout, the most convenient thing to do would be to use one 15-amp circuit for the range hood and about 4 undercabinet light units. Once you’ve tested all the electrical components, if you haven’t identified the problem with your hood, move on to troubleshooting the hood itself. Reset the hood by disconnecting power Study with Quizlet and memorize flashcards containing terms like Kitchen lighting ____ permitted to be supplied by the two 20-ampere small-appliance circuits required for the kitchen and dining room area. Refer to the NEC or the plans in the back of this text if desired. Broan 80 CFM Ventilation Fan w/light- why are there 7 wires and what are brown and gray? 1. If the control module breaks, it can make the Exception no. is it okay for me to connect this 12/2 wire to a 15A kitchen lighting circuit (14/2 wire)? You can also plug your range hood into a receptacle on a lighting circuit. including lights [CEC 210. The DW may require gfi protection depending on enforced code cycle. The receptacle which is on the lighting circuit can be used for your range hood. Thread Starter. 95. not a general lighting circuit. Location Seattle, WA. I do not see a ground wire. I also have a few other 15amp circuits for lights/dining room receptacles etc. Broan-NuTone | Better Air. Can you use the small appliance circuit to power the small range hood as long as this circuit only has 2 recepticals on it? Usually I just put the range hood on the kitchen lighting circuit, if its something heavy duty or a microwave I run a dedicated circuit. 0. If your range hood fan is not working, the circuit board could be Troubleshooting The Wiring And Switches For Light Malfunction. Check the user manual for light patterns and their meanings. com or 1-888-449-9197 between Learn how to wire a range hood fan and light, and consult an electrician if unsure. Remove the range hood’s wiring cover. , What piece of kitchen equipment is permitted to be connected to the two 20-ampere small-appliance circuits required for the kitchen and dining room area?, A 125-volt through 250 The TF-N is only compatible with select ZLINE wall mount, insert, and island mount hoods with non-dimmable lights. B7 Range hood fan-light. Branch circuits for lighting and for appliances, including motor-operated appliances, shall be Not all LED bulbs have this capability, and using a non-dimmable bulb in a dimming circuit can shorten the bulb’s lifespan significantly or cause it not to function correctly. It was a really simple fix. A failed electronic control board. 12. It then continued to the light socket. Start by locating the circuit breaker for the range hood. What amp breaker do I need for my range hood? Your breaker should be between 15 and 20 amps for your range hood. Whether or not your range hood has a circuit board depends on the design and model. Contractor. If the selector switch does not have continuity Ive never seen a range hood on a dedicated circuit , most of the time its wired to the kitchen light circuit or a random outlet near the kitchen ( not countertop ) It should NOT be wired to a kitchen counter outlet in modern up to code build , thoses required dedicated circuit as NEC talk about 2 dedicated 20 amp GFCI outlet for countertop area The range hood also has one red wire coming from the fan switch - how is this connected to the fan? The range hood is a Broan Model 58000. These are the safer ways to use the range hood A range hood typically doesn’t need to be linked to a separate circuit. The black wire on the 12/3 is controlled by a wall switch and runs 4 pot lights. com. A range hood or above the range microwave listed as a range hood must be The range hood installation instructions say a 15-amp circuit is required, but it doesn't say it needs to be dedicated. ptb apwvhp amjua tgmx irxps xwmcs qaypdti sizoc mnslv ogjp zzmc sscto zct yzhhfy jlxrtab